You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
[BUG][TGL]Wov trigger volume is different with format s16_le/24_le/32_le. #3112
Describe the bug
When set wov capture volume under 60, wov can barely be triggered with format s16_le.
set volume under 30, wov can barely be triggered with format s24_le.
At the same time, wov with format s32_le is so easy to be triggered even no need to make some obvious noise.
To Reproduce
Boot up system
Set capture volume "PGA9.0 9" 50
Run wov test with format 16_le/24_le/32_le via command "arecord -Dhw:0,100 -M -N -f s32_le -r 16000 -i -vvv -c2 --buffer-size=80000 ./tmp.wav"
Turn down the "PGA9.0 9" to 30 and repeat step 3.
Turn down the "PGA9.0 9" to 20 and repeat step 3.
Reproduce rate
5/5
Expected result
wov with format s16/s24/s32 can be triggered.
Actual result
When set wov capture volume under 60, wov can barely be triggered with format s16_le.
set volume under 30, wov can barely be triggered with format s24_le.
At the same time, wov with format s32_le is so easy to be triggered even no need to make some obvious noise.
changed the title [-][BUG][TGL]It's hard to trigger wov when set volume under 30 with format 16_le/24_le but s32_le can be auto triggered.[/-][+][BUG][TGL]Wov trigger volume is different with format s16_le/24_le/32_le.[/+]on Jun 30, 2020
Activity
[-][BUG][TGL]It's hard to trigger wov when set volume under 30 with format 16_le/24_le but s32_le can be auto triggered.[/-][+][BUG][TGL]Wov trigger volume is different with format s16_le/24_le/32_le.[/+]tlauda commentedon Jun 30, 2020
@YvonneYang2 Is it a regression?
ClarexZhou commentedon Jun 30, 2020
This isn't a regression, always behavior like this.
keyonjie commentedon Jun 30, 2020
Hi @tlauda @ClarexZhou I just root caused and will provide a PR to fix this soon, so you can not put effort to it atm.
keyonjie commentedon Jun 30, 2020
PR #3116 is submitted to fix the issue here.
ClarexZhou commentedon Jun 30, 2020
Verified, error not seen with PR #3116
keyonjie commentedon Jul 8, 2020
Close it as #3116 was merged.