[BUG][TGL]Terminal shows "cannot load mixer controls: Device or resource busy" when open alsamixer when pm runtime in suspended status. #2221
@YvonneYang2 Could you list which mixer will you get "cannot load mixer controls: Device or resource busy" error? I think if should not be an issue if it is an volatile mixer.
@bardliao
Diff and verified the amixer info of error reproduced and error not reproduced. The value of name='Left/Right Spk Switch' will cause the issue. With value off, issue can be reproduced, while with on, error not seen.
When error seen, cannot get these values of below numid:
numid=83,iface=MIXER,name='Left ADC PVDD'
numid=84,iface=MIXER,name='Left ADC TEMP'
numid=95,iface=MIXER,name='Left BDE Active Level'
numid=71,iface=MIXER,name='Left FS Max Volume'
numid=72,iface=MIXER,name='Left Output Voltage'
numid=70,iface=MIXER,name='Left Speaker Volume'
numid=27,iface=MIXER,name='Right ADC PVDD'
numid=28,iface=MIXER,name='Right ADC TEMP'
numid=39,iface=MIXER,name='Right BDE Active Level'
numid=15,iface=MIXER,name='Right FS Max Volume'
numid=16,iface=MIXER,name='Right Output Voltage'
numid=14,iface=MIXER,name='Right Speaker Volume'
Activity
YvonneYang2 commentedon Jun 22, 2020
Error still seen with kernel + tgl-006-stable branch.
RanderWang commentedon Jun 23, 2020
it is caused by inaccessible register in max98373. I am debugging driver
YvonneYang2 commentedon Jun 23, 2020
Verified #2226 , issue can be fixed.
bardliao commentedon Jun 23, 2020
@YvonneYang2 Could you list which mixer will you get "cannot load mixer controls: Device or resource busy" error? I think if should not be an issue if it is an volatile mixer.
YvonneYang2 commentedon Jun 28, 2020
@bardliao
Diff and verified the amixer info of error reproduced and error not reproduced. The value of name='Left/Right Spk Switch' will cause the issue. With value off, issue can be reproduced, while with on, error not seen.
When error seen, cannot get these values of below numid:
error_seen.txt
error_not_seen.txt