Describe the bug
When a tmy3 file formatted in epw is read, the precipitable_water is not converted from mm to cm, and it results in diverging results for spectral mismatch factor (like negative factor for instance), then resulting in negative 'effective_irradiance' results
To Reproduce
Steps to reproduce the behavior:
Create a ChainModel object with a .epw weather file, coming from TMY3 data and imported with 'pvlib.iotools.epw.read_epw()'
Run the model
Check for inconsistencies in effective_irradiance with 'chain1.effective_irradiance.loc[chain1.effective_irradiance<0]'
or
Run the code attached
Expected behavior
All the effective_irradiance should be positive or null.
@roelloonen would appreciate your input here. To me, it appears that EnergyPlus is converting the unit for precipitable water in TMY2 files from mm to cm. The NREL documentation for TMY2 states mm, although I've not been able to recover a TMY2 file and confirm.
The more general inputs of my model are in the attached text file (just replace .txt with .py to run with python).
I agree, in TMY2 files precipitable water is in mm. But in TMY3 files it is in cm according to the nrel user's manual.
The EnergyPlus doc states that data should be in mm (https://energyplus.net/sites/all/modules/custom/nrel_custom/pdfs/pdfs_v9.1.0/AuxiliaryPrograms.pdf , cf p.14).
I guess EnergyPlus or NREL made an error about the unit when writing the doc and it resulted in bad conversion, because the epw file coming from tmy2 seems to be to ok (in cm), but not the epw files coming from tmy3 (in mm)
The issue can be solved just by adding two lines in pvlib.iotools.epw.read_epw():
if 'tmy3' in filename.lower():
data['precipitable_water'] = data['precipitable_water']/10
Nevertheless, if the issue comes from an error in the conversion of epw files by EnergyPlus, maybe it will be corrected soon, and these two lines will have to be removed.
Yes, what @tylunel writes is in line with my understanding.
The proposed modification seems to work. A drawback is that it makes an exception for TMY3, which is arguably among the most commonly used data sources for EPW, but certainly not the only one: https://energyplus.net/weather/sources
I will contact one of the developers of the EPW format. Maybe he can shed some more light on this issue.
EnergyPlus documentation says mm is the unit for precipitable water.
TMY2 documentation says mm was used.
TMY3 documentation says cm is currently used.
pvlib functions expect cm.
@tylunel note indicates that TMY2 files obtained in EPW format have the units in cm, and TMY3 files in EPW format have the units in mm. This seems backwards, but inspecting the files @tylunel linked supports this description.
Does EnergyPlus have the units switched for TMY2 and TMY3 in EPW format?
I will contact one of the developers of the EPW format. Maybe he can shed some more light on this issue.
The feedback I got is that the precipitable water in the EPW files based on TMY3 was indeed converted incorrectly.
There is apparently no possibility to change the data on www.energyplus.net, but the corrected TMY3 files on http://climate.onebuilding.org/ will be reposted.
As a consequence, there will soon be corrected TMY3.epw files and original/"wrong" TMY3.epw files. In this case, the correction based on filename is no longer a failproof solution.
Would there maybe be a way to infer from the precipitation data which of the two units is clearly the most realistic one? Or perhaps that adds way too much complexity for the problem we are trying to solve?
I don't think that the read_epw function should attempt to correct errors in EPW data files. I think that will only cause trouble for pvlib down the road.
I'm OK if we want to add a Note to the docstring about TMY3 files from energyplus.net having a known error, and providing helpful suggestions for handling the error.
As far as I know, precipitable water data is only used as input in atmosphere.first_solar_spectral_correction() and in atmosphere.kasten96_lt(). atmosphere.first_solar_spectral_correction() contains a kind of pre-process on precipitable_water data at the beginning of the function :
# *** Pwat *** (=precipitable water)
# Replace Pwat Values below 0.1 cm with 0.1 cm to prevent model from
# diverging"
if np.min(pw) < 0.1:
pw = np.maximum(pw, 0.1)
warn('Exceptionally low Pwat values replaced with 0.1 cm to prevent' +
' model divergence')
# Warn user about Pwat data that is exceptionally high
if np.max(pw) > 8:
warn('Exceptionally high Pwat values. Check input data:' +
' model may diverge in this range')
Maybe we could add a line to change the highest values as it is done for value lower than 0.1 ? It would give the simple following line :
pw = np.minimum(pw, 8)
This way the model will not diverge and will not return impossible spectral mismatch factor (like negative). Still the result will be wrong, but I guess it is better than getting impossible factor resulting in impossible effective_irradiance at the end.
Then with the warning and the adding in the docstring, it may be enough for the user to understand that something is wrong.
Maybe we could add a line to change the highest values as it is done for value lower than 0.1 ? It would give the simple following line :
pw = np.minimum(pw, 8)
I'd prefer to add a check and warning to read_epw, because we know there are EPW files with bad values that aren't likely to go away.
I'd rather not overwrite values inside the spectral mismatch function, the warning seems sufficient to me.
I think it's reasonable to add a pw = np.minimum(pw, 8) line to first_solar_spectral_correction. I also think it's reasonable to return nan for values outside the limits of the algorithm. I'm not inclined to change the read_epw function, and I'm neutral on changing its docstring.
I think it's reasonable to add a pw = np.minimum(pw, 8) line to first_solar_spectral_correction.
OK if we provide pw_min and pw_max as kwargs, if so we should add kwargs for the air mass limits as well. I am reluctant to second-guess what a user wants from the function.
I also think it's reasonable to return nan for values outside the limits of the algorithm.
That's a challenge. The original paper developed and validated for 0.1 <=pw <= 5, but who's to say the model is invalid outside that range.
@wholmgren and I talked about this in person (still happens sometimes :). Neither of us are strongly opposed to any of the following options:
add a note to read_epw about older TMY files from energyplus.net
add pw = np.minimum(pw, max_pw) to first_solar_spectral_correction and expose max_pw as a kwarg. Could use this opportunity to also implement min_pw, min_am and max_am but that could be done in a later PR. Default of 8. Return np.nan when inputs are outside the accepted pw range, and warning.
We both think the better course for read_epw is to return exactly what is in the EPW file, rather than attempt to check or correct the content.
Activity
cwhanse commentedon Sep 30, 2019
@roelloonen would appreciate your input here. To me, it appears that EnergyPlus is converting the unit for precipitable water in TMY2 files from mm to cm. The NREL documentation for TMY2 states mm, although I've not been able to recover a TMY2 file and confirm.
tylunel commentedon Sep 30, 2019
My weather input is as follows :
pvlib.iotools.epw.read_epw('https://energyplus.net/weather-download/north_and_central_america_wmo_region_4/USA/MA/USA_MA_Boston-Logan.Intl.AP.725090_TMY3/USA_MA_Boston-Logan.Intl.AP.725090_TMY3.epw')
The more general inputs of my model are in the attached text file (just replace .txt with .py to run with python).
I agree, in TMY2 files precipitable water is in mm. But in TMY3 files it is in cm according to the nrel user's manual.
The EnergyPlus doc states that data should be in mm (https://energyplus.net/sites/all/modules/custom/nrel_custom/pdfs/pdfs_v9.1.0/AuxiliaryPrograms.pdf , cf p.14).
I guess EnergyPlus or NREL made an error about the unit when writing the doc and it resulted in bad conversion, because the epw file coming from tmy2 seems to be to ok (in cm), but not the epw files coming from tmy3 (in mm)
tylunel commentedon Sep 30, 2019
The issue can be solved just by adding two lines in pvlib.iotools.epw.read_epw():
Nevertheless, if the issue comes from an error in the conversion of epw files by EnergyPlus, maybe it will be corrected soon, and these two lines will have to be removed.
roelloonen commentedon Sep 30, 2019
Yes, what @tylunel writes is in line with my understanding.
The proposed modification seems to work. A drawback is that it makes an exception for TMY3, which is arguably among the most commonly used data sources for EPW, but certainly not the only one: https://energyplus.net/weather/sources
I will contact one of the developers of the EPW format. Maybe he can shed some more light on this issue.
cwhanse commentedon Sep 30, 2019
OK, I'm thoroughly confused. Facts:
@tylunel note indicates that TMY2 files obtained in EPW format have the units in cm, and TMY3 files in EPW format have the units in mm. This seems backwards, but inspecting the files @tylunel linked supports this description.
Does EnergyPlus have the units switched for TMY2 and TMY3 in EPW format?
cwhanse commentedon Sep 30, 2019
sorry misclicked.
roelloonen commentedon Oct 3, 2019
The feedback I got is that the precipitable water in the EPW files based on TMY3 was indeed converted incorrectly.
There is apparently no possibility to change the data on www.energyplus.net, but the corrected TMY3 files on http://climate.onebuilding.org/ will be reposted.
As a consequence, there will soon be corrected TMY3.epw files and original/"wrong" TMY3.epw files. In this case, the correction based on filename is no longer a failproof solution.
Would there maybe be a way to infer from the precipitation data which of the two units is clearly the most realistic one? Or perhaps that adds way too much complexity for the problem we are trying to solve?
cwhanse commentedon Oct 3, 2019
I don't think that the
read_epwfunction should attempt to correct errors in EPW data files. I think that will only cause trouble for pvlib down the road.I'm OK if we want to add a Note to the docstring about TMY3 files from energyplus.net having a known error, and providing helpful suggestions for handling the error.
tylunel commentedon Oct 3, 2019
As far as I know, precipitable water data is only used as input in atmosphere.first_solar_spectral_correction() and in atmosphere.kasten96_lt(). atmosphere.first_solar_spectral_correction() contains a kind of pre-process on precipitable_water data at the beginning of the function :
# *** Pwat *** (=precipitable water)
# Replace Pwat Values below 0.1 cm with 0.1 cm to prevent model from
# diverging"
Maybe we could add a line to change the highest values as it is done for value lower than 0.1 ? It would give the simple following line :
pw = np.minimum(pw, 8)
This way the model will not diverge and will not return impossible spectral mismatch factor (like negative). Still the result will be wrong, but I guess it is better than getting impossible factor resulting in impossible effective_irradiance at the end.
Then with the warning and the adding in the docstring, it may be enough for the user to understand that something is wrong.
cwhanse commentedon Oct 3, 2019
I'd prefer to add a check and warning to
read_epw, because we know there are EPW files with bad values that aren't likely to go away.I'd rather not overwrite values inside the spectral mismatch function, the warning seems sufficient to me.
wholmgren commentedon Oct 3, 2019
I think it's reasonable to add a
pw = np.minimum(pw, 8)line tofirst_solar_spectral_correction. I also think it's reasonable to return nan for values outside the limits of the algorithm. I'm not inclined to change theread_epwfunction, and I'm neutral on changing its docstring.cwhanse commentedon Oct 3, 2019
OK if we provide
pw_minandpw_maxas kwargs, if so we should add kwargs for the air mass limits as well. I am reluctant to second-guess what a user wants from the function.That's a challenge. The original paper developed and validated for 0.1 <=pw <= 5, but who's to say the model is invalid outside that range.
cwhanse commentedon Oct 9, 2019
@wholmgren and I talked about this in person (still happens sometimes :). Neither of us are strongly opposed to any of the following options:
read_epwabout older TMY files from energyplus.netpw = np.minimum(pw, max_pw)tofirst_solar_spectral_correctionand exposemax_pwas a kwarg. Could use this opportunity to also implementmin_pw,min_amandmax_ambut that could be done in a later PR. Default of 8. Returnnp.nanwhen inputs are outside the acceptedpwrange, andwarning.We both think the better course for
read_epwis to return exactly what is in the EPW file, rather than attempt to check or correct the content.* Fix for issue (pvlib#782)
* fix for issue pvlib#782
* fix for issue pvlib#782
* fix for issue pvlib#782
* fix for issue pvlib#782
* Fix for issue pvlib#782
* Fix for issue #782 (#816)
* Fix for issue pvlib#782 (pvlib#816)
Snow coverage model from SAM (#764)