Effective irradiance units #472

Closed

Description

@cwhanse

pvsystem.sapm expected effective_irradiance in units of suns (1 sun = 1000 W/m2). pvsystem.calcparams_desoto expects effective_irradiance in W/m2. I want to change to consistent units for effective irradiance.

Preferences for suns or W/m2?

Activity

  1. markcampanelli commented on Jun 2, 2018

    @markcampanelli
    Contributor

    It seems like the Desoto quantity is an actual broadband total irradiance, possibly normalized but not "effective"---poa_global with irrad_ref in pvlib or S or S/Sref here, while the unitless SAPM quantity seems more properly called an "effective" irradiance as a ratio of currents.

  2. markcampanelli commented on Jun 3, 2018

    @markcampanelli
    Contributor

    Also, calling this "effective irradiance" might be confused with the G_{eff} appearing in the DeSoto's master's thesis, which appears to have a different definition.

  3. markcampanelli commented on Jun 3, 2018

    @markcampanelli
    Contributor

    It appears above that I misunderstood the definition of the parameter S (it is "absorbed", and thus includes some losses). My underlying concern stands though, as it seems that we are struggling with making a consistent function API out of different models that construct "analogous" parameters somewhat differently. Because I am not an everyday user of some/all of DeSoto vs. CEC vs. PVsyst, I don't think I should comment on what is better: consistent API or fidelity to the original model formulation.

    I will also point out that my difficulties wrapping my head around these various irradiance definitions is what lead me to yet another formulation of "effective irradiance". This formulation does not eliminate all the various issues either, but in some measurement setups it is significantly easier to reason about.

  4. adriesse commented on Jun 3, 2018

    @adriesse
    Member

    I would prefer things called "irradiance" to have units of W/m2.

  5. cwhanse commented on Jun 4, 2018

    @cwhanse
    MemberAuthor

    @thunderfish24 we are resolving the conflict about the irradiance input to calcparams_desoto as part of #462 - see my comment on this topic late in the discussion.

  6. cwhanse commented on Jun 4, 2018

    @cwhanse
    MemberAuthor

    As it is now, calcparams_desoto accepts irradiance in W/m2, sapm expects irradiance in suns. If we agree, the change will be to sapm to accept irradiance in W/m2. The suns unit in sapm is likely a holdover from transcribing PVLib for matlab to python.

  7. adriesse commented on Jun 4, 2018

    @adriesse
    Member

    The original sapm report uses suns too. Maybe there is a role for an effective_irradiance_factor to link the two.

  8. cwhanse commented on Jun 4, 2018

    @cwhanse
    MemberAuthor

    That's an idea. If we want to retain the units published for each model, I could see implementing a private helper function to convert units based on model. Not sure where it would plug into the model chain workflow, though.

  9. wholmgren commented on Jun 4, 2018

    @wholmgren
    Member

    I prefer effective_irradiance in units of W/m^2. I prefer prepending or appending "normalized" for unitless quantities.

  10. adriesse commented on Jun 6, 2018

    @adriesse
    Member

    Here another thought out of the left corner. Perhaps these functions should have just irradiance as a parameter, without further details. There is a similar situation with inverters, where it is clear there are some losses between the array and the power electronics, but the input to the inverter is just called p_dc, not p_dc_after_wiring_loss.

  11. cwhanse commented on Jun 6, 2018

    @cwhanse
    MemberAuthor

    @adriesse I think that would be a step back for pvlib in terms of our objective to clarify the component models and their usage. For the inverter example you cite, I'd be inclined to add clarity to the p_dc input.

  12. adriesse commented on Jun 6, 2018

    @adriesse
    Member

    I admit I didn't have that objective foremost in mind.

  13. cwhanse commented on Jun 11, 2018

    @cwhanse
    MemberAuthor

    For this issue, my plan is to implement effective_irradiance in units of W/m2 for SAPM. I believe these changes will make the use of effective irradiance consistent throughout pvlib:

    • change pvsystem.sapm to expect effective_irradiance in units of W/m2
    • no change needed to pvsystem.sapm_celltemp
    • clarify signature of pvsystem.samp_effective_irradiance to add units to input parameter descriptions.
  14. added this to the 0.6.1 milestone on Sep 12, 2018
  15. modified the milestones: 0.6.1, 0.7.0 on Nov 3, 2018