Skip to content

spectrum.spectrl2 calculates negative irradiance for angle of incidence outside +/- 90° #1348

Closed

Description

@cweickhmann

When using pvlib (but also the spectrl2 implementation provided by NREL), I obtain negative Irradiance for a north-facing panel.
From @kevinsa5 's reply on StackOverflow I take that this is in fact not intended.

In the example code below, the angle of incidence is calculated as values around 115°, so exceeding a possible (implicitly assumed) +/- 90° bound (sun behind panel).

This seems to be left open in the original report (Bird & Riordan, 1984).

The direct irradiance I_d (of a horizontal panel, Eq 2-1) is obtained by multiplying by cosine of the sun zenith angle. I'd guess that setting that value strictly to zero for angles when cosZ is negative would not be too much of a stretch.

Then, the direct irradiance I_d goes into (Eq 3-18):

I_T(t) = I_d*cos(aoi) + I_s * ( (I_d*cos(aoi) / (H_0*D*cos(Z)) ) + 0.5*(1+cos(t)) * (1 - I_d/(H_0*D)) + 0.5 * I_T0 * r_g * (1-cos(t))

As such, when you view the angle of incidence aoi as the analogue of the sun zenith angle in the prior example, the two first terms of the diffuse irradiation (Eq 3-18) would become zero, which - again - for the direct irradiance would kind of make sense. What remains of (Eq 3-18) would be

I_T(t) = 0 + 0 + 0.5*(1+cos(t))*(1 - 0) + 0.5*I_T0*r_g*(1-cos(t))

I'm not from the field, so I'm very, very wary about the implications of such a work-around suggestion. Can anyone with a proper background comment on this? (Maybe it's the future of air conditioning :-D)

MWE based on the tutorial below

## Using PV Lib

from pvlib import spectrum, solarposition, irradiance, atmosphere
import pandas as pd
import matplotlib.pyplot as plt

# assumptions from the technical report:
lat = 49.88
lon = 8.63
tilt = 45
azimuth = 0 # North = 0
pressure = 101300  # sea level, roughly
water_vapor_content = 0.5  # cm
tau500 = 0.1
ozone = 0.31  # atm-cm
albedo = 0.2

times = pd.date_range('2021-11-30 8:00', freq='h', periods=6, tz="Europe/Berlin") # , tz='Etc/GMT+9'
solpos = solarposition.get_solarposition(times, lat, lon)
aoi = irradiance.aoi(tilt, azimuth, solpos.apparent_zenith, solpos.azimuth)

# The technical report uses the 'kasten1966' airmass model, but later
# versions of SPECTRL2 use 'kastenyoung1989'.  Here we use 'kasten1966'
# for consistency with the technical report.
relative_airmass = atmosphere.get_relative_airmass(solpos.apparent_zenith,
                                                   model='kasten1966')

spectra = spectrum.spectrl2(
    apparent_zenith=solpos.apparent_zenith,
    aoi=aoi,
    surface_tilt=tilt,
    ground_albedo=albedo,
    surface_pressure=pressure,
    relative_airmass=relative_airmass,
    precipitable_water=water_vapor_content,
    ozone=ozone,
    aerosol_turbidity_500nm=tau500,
)

plt.figure()
plt.plot(spectra['wavelength'], spectra['poa_global'])
plt.xlim(200, 2700)
# plt.ylim(0, 1.8)
plt.title(r"2021-11-30, Darmstadt, $\tau=0.1$, Wv=0.5 cm")
plt.ylabel(r"Irradiance ($W m^{-2} nm^{-1}$)")
plt.xlabel(r"Wavelength ($nm$)")
time_labels = times.strftime("%H:%M %p")
labels = [
    "AM {:0.02f}, Z{:0.02f}, {}".format(*vals)
    for vals in zip(relative_airmass, solpos.apparent_zenith, time_labels)
]
plt.legend(labels)
plt.show()

Figure_ne

Activity

  1. kandersolar commented on Dec 1, 2021

    @kandersolar
    Member

    Thanks @cweickhmann! I want to take a closer look at the technical report to be sure, but on a first glance I think the problem here is the same one solved by the line marked with # GH 526 in irradiance.haydavies:

    if projection_ratio is None:
    cos_tt = aoi_projection(surface_tilt, surface_azimuth,
    solar_zenith, solar_azimuth)
    cos_tt = np.maximum(cos_tt, 0) # GH 526
    cos_solar_zenith = tools.cosd(solar_zenith)
    Rb = cos_tt / np.maximum(cos_solar_zenith, 0.01745) # GH 432

    Note that, even though spectrum.spectrl2 uses irradiance.haydavies under the hood, the above branch is not hit because spectrl2 passes in a pre-calculated projection_ratio. So I think clipping the projection to be non-negative before passing it to haydavies would solve the problem. The # GH 432 line might be desirable as well, though I don't think it's relevant for this issue.

    Does anyone have qualms about us deviating from the reference by implementing that fix and making a note about it in the docstring? aoi > 90 is hardly an uncommon occurrence, even for arrays that aren't high-latitude and facing north.

  2. cwhanse commented on Dec 1, 2021

    @cwhanse
    Member

    deviating from the reference by implementing that fix and making a note about it

    I support that.

  3. added this to the 0.9.1 milestone on Dec 4, 2021