Skip to content

Apparent numerical instability in I_mp calculation using PVsyst model #1087

Closed

Description

@markcampanelli

Describe the bug

I used these parameters in pvlib.pvsystem.calcparams_pvsyst() in order to calculate I_mp vs. T using pvlib.pvsystem.singlediode() with effective_irradiance fixed at 1000 W/m^2 and temp_cell having 1001 values ranging from 15 to 50 degC:

{'alpha_sc': 0.006, 'gamma_ref': 1.009, 'mu_gamma': -0.0005, 'I_L_ref': 13.429, 'I_o_ref': 3.719506010004821e-11, 'R_sh_ref': 800.0, 'R_sh_0': 3200.0, 'R_s': 0.187, 'cells_in_series': 72, 'R_sh_exp': 5.5, 'EgRef': 1.121, 'irrad_ref': 1000, 'temp_ref': 25}

My purpose was to investigate the temperature coefficient of I_mp, and I got the following result, which appears to suffer from a numeric instability:

image

For comparison, the corresponding V_mp vs. T plot:

image

To Reproduce

Run the above calculations using the parameters provided.

Expected behavior

Better numerical stability in I_mp vs. T.

Screenshots

See above.

Versions:

  • pvlib.__version__: 0.8.0
  • numpy.__version__: 1.19.2
  • scipy.__version__: 1.5.2
  • pandas.__version__: 1.1.3
  • python: 3.8.5

Additional context

I was going to attempt a numerical computation of the temperature coefficient of I_mp for a model translation to the SAPM. I have seen reports from CFV in which this coefficient is actually negative, and I have computed it alternately using the P_mp and V_mp temperature coefficients, and gotten a negative value for this particular PV module. Despite the apparent numerical instability in the above plot, it still suggests that the coefficient should be positive, not negative. Perhaps I am missing something here?

Also, I have not dug deep enough to figure out if the underlying issue is in pvlib.pvsystem.singlediode().

Activity

  1. cwhanse commented on Nov 5, 2020

    @cwhanse
    Member

    Confirmed. Looks like it's a lack of convergence in pvlib.singlediode._lambertw. Some time ago a similar issue was reported for PVLib Matlab, I think we bumped up the iteration count to fix it.

    If you set pvlib.singlediode(..., method='brentq',...) the noise smooths away.

  2. markcampanelli commented on Nov 5, 2020

    @markcampanelli
    ContributorAuthor

    @cwhanse Thanks. method='brentq' fixed the issue for me too. :)

    Since you're from Sandia, do have any insight about a "typical" sign of the T-coef for I_mp in the SAPM? It seems like the sign is positive for the PVsyst model and negative for the SAPM (both in SOME CFV reports and by taking the derivative of P_mp = I_mp * V_mp w.r.t. T and solving for dI_mp/ dT).

    UPDATE: With the I_mp calculation correction, it appears that I get a consistent + sign for the I_mp temperature coefficient in both computational methods. However, I do see this reported as a negative value in some places.

  3. cwhanse commented on Nov 5, 2020

    @cwhanse
    Member

    I don't know that theory predicts a sign for this temperature coefficient.

    For SAPM, when Sandia fits this model using outdoor measurements, a value is determined by fitting a line to Imp vs. cell temperature (backed out of Isc, Voc values). I've argued that given the resolution of measurements, the technique for determining cell temperature and maximum power point, and the regression method, that the value is usually statistically indistinguishable from zero.

    For CFV-produced Pvsyst parameters, my guess is that CFV is determining alpha_imp by fitting a line to the Imp vs. cell temperature data (IEC61853 matrix test results using an indoor flasher with temperature variation control), which is the same method used by Sandia for the SAPM. Happy to connect you with CFV and you can ask them.

  4. markcampanelli commented on Nov 5, 2020

    @markcampanelli
    ContributorAuthor

    Thanks for sharing your understanding @cwhanse. I think I will have a convo with Daniel C. Zirzow at CFV at some point in the near future.

    Should I close this issue, or should it become a PR to change defaults to better ensure convergence?

  5. cwhanse commented on Nov 5, 2020

    @cwhanse
    Member

    Leave it open, there's a pvlib issue to be addressed.

    I tracked down the source of the oscillatory behavior to this line.

            argW = Rs[idx_p] * I0[idx_p] / (
                        a[idx_p] * (Rs[idx_p] * Gsh[idx_p] + 1.)) * \
                   np.exp((Rs[idx_p] * (IL[idx_p] + I0[idx_p]) + V[idx_p]) /
                          (a[idx_p] * (Rs[idx_p] * Gsh[idx_p] + 1.)))
    

    It's a product of two terms:
    constant factor : Rs * I0 / (a (Rs Gsh + 1)) which is very small (~1E-10) and
    exponential factor: np.exp( (Rs * (IL + I0) + V) / (a * (Rs * Gsh + 1)) ) which is quite large (~1E+10), since the argument is ~20.

    The constant factor increases smoothly with cell temperature, as expected.

    The argument of the exponential term decreases with temperature but not smoothly. The cause seems to be that Vmp (V in that line of code) decreases but not smoothly. Vmp is calculated using pvlib.tools._golden_sect_DataFrame. I suspect the convergence of this root finder is the culprit.

  6. markcampanelli commented on Nov 5, 2020

    @markcampanelli
    ContributorAuthor

    @cwhanse An incidental colleague of mine (Ken Roberts) figured out a way around the numerical convergence issues with using the LambertW function for solving the single diode equation. I have never had the time to do it full justice in code (I use simple newton in PVfit), but this "Log Wright Omega" function might be worth looking into for pvlib. Here are some references he shared with me. He was so pleasant to work with and I found his exposition very approachable.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment