I can never get out of the while ((lastTimeStamp = inlet.pull_sample(sample, 0.0f)) != 0) loop because I'm Processing the samples slower than they are coming in.
Solution A: do not push sample processing logic into Unity - heavy data post-processing could be done in more efficient environments due to data processing - e.g. matlab\Julia\Python ❓ This might result in feature streams with lower frequencies (30 - 100Hz) which could be comfortable processed by Update rates of 30/60/90 Hz of a game loop.
Soultion B: Using a thread based wrapper for a LSL inlet.
voidStart(){// contains all the thread logicmySampleAquisitionJob=newFloatSampleAquisition(streamInlet);mySampleAquisitionJob.Start();//start the thread and try pulling}voidUpdate(){if(mySampleAquisitionJob.HasData){// this takes care of thread locking etc.float[]data=mySampleAquisitionJob.GetData();// data got copied in the unity main thread }}
I do all my signal processing in Python (mostly using NeuroPype). It streams the result out via a 'type="Control"' Outlet. These streams are always between 10 and 80 Hz.
I was able to escape the while loop by commenting out my line in Process that printed the value via Debug.Log. I guess Debug.Log is too slow to be called multiple times in each game tick.
I've since modified my Process function to simply take the value and store it as a member variable and toggle a hasNewData switch. Then at the end of Update (i.e., after pullSamples()), if (hasNewData) {do something with lastSample;}.
I don't know if you've ever encountered this, but sometimes when I start up a program that gets an LSL Inlet, it seems to get lots of data really quickly at the beginning, much faster than it is being sent out via the outlet, then eventually it catches up and the inlet data rate matches the outlet data rate. I assume this has something to do with LSL's data buffering and my application's new inlet assuming the role of a recently-destroyed inlet and picking up all the data since the last inlet was destroyed.
I was able to escape the while loop by commenting out my line in Process that printed the value via Debug.Log. I guess Debug.Log is too slow to be called multiple times in each game tick.
Instead of using the Debug.Log, I would suggest to use an custom inspector with a value field showing the latest value of your stream within the inspector of your components.
Code looks like this:
publicclassYourScript:MonoBehaviour{[HideInspector]// to get a read only fieldpublicfloatlatestLSLSample=0f;voidUpdate(){// Update the value from your lsl values.... latestSample=GetTheLSLValue();}}[CustomInspector(typeof(YourScript))]publicclassInspectorForYourScript:Editor{publicoverrideOnInspectorGUI(){varyourScript=targetasYourScript;// Show the default Inspectorbase.OnInspectorGUI();// shows the hidden property as a read only fieldEditorGUILayout.FloatField(yourScript.latestValue,"Latest Value from LSL");}}
this seems to be more efficient than a debug log call.
For the future, I'm planning to provide a little chart implementation which can be used within the Editor and the Game logic for visualisation purpose.
But this solves the issue just for the case, you got this issue whenever you got a bit more processing logic - which takes also a bit more.
The second issue:
it seems to get lots of data really quickly at the beginning, much faster than it is being sent out via the outlet, then eventually it catches up and the inlet data rate matches the outlet data rate
Naive solution: I would pull all samples at the start of the application and throw them away since we don't want to record something.
Interesting phenomena, actually intended, I guess their should be an option for that.... I will take a look. I thought their was a config file for LSL which could be used to define things like how much data should be cached...
Activity
cboulay commentedon Jan 5, 2017
I do all my signal processing in Python (mostly using NeuroPype). It streams the result out via a 'type="Control"' Outlet. These streams are always between 10 and 80 Hz.
I was able to escape the while loop by commenting out my line in Process that printed the value via Debug.Log. I guess Debug.Log is too slow to be called multiple times in each game tick.
I've since modified my Process function to simply take the value and store it as a member variable and toggle a hasNewData switch. Then at the end of Update (i.e., after pullSamples()),
if (hasNewData) {do something with lastSample;}.I don't know if you've ever encountered this, but sometimes when I start up a program that gets an LSL Inlet, it seems to get lots of data really quickly at the beginning, much faster than it is being sent out via the outlet, then eventually it catches up and the inlet data rate matches the outlet data rate. I assume this has something to do with LSL's data buffering and my application's new inlet assuming the role of a recently-destroyed inlet and picking up all the data since the last inlet was destroyed.
coprnicvs commentedon Jan 5, 2017
to this:
Instead of using the Debug.Log, I would suggest to use an custom inspector with a value field showing the latest value of your stream within the inspector of your components.
Code looks like this:
this seems to be more efficient than a debug log call.
For the future, I'm planning to provide a little chart implementation which can be used within the Editor and the Game logic for visualisation purpose.
But this solves the issue just for the case, you got this issue whenever you got a bit more processing logic - which takes also a bit more.
The second issue:
Naive solution: I would pull all samples at the start of the application and throw them away since we don't want to record something.
Interesting phenomena, actually intended, I guess their should be an option for that.... I will take a look. I thought their was a config file for LSL which could be used to define things like how much data should be cached...