You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Import/export of BaudRate_xx in EDS not working #301
According to CiA 306 the valid baudrate keywords in the DeviceInfo section are:
BaudRate_10, BaudRate_20, BaudRate_50, etc
However, these are not recognized by the import_eds() method, instead import_eds() recognizes:
Baudrate_10, Baudrate_20, Baudrate_50, etc
(note the casing of "R"/"r")
Also the export_eds() record will export the names as:
Baudrate_10, Baudrate_20, Baudrate_50, etc
This means that if I import an EDS file and then just export it to a new filename this information gets lost.
After a quick search it seems that yes the DeviceInfo should have BaudRate_XX, i.e., in camel case.
You can make a PR with the changes needed to support this, or wait and maybe during the weekend I can have a look.
Activity
af-silva commentedon Mar 14, 2022
Hi @Sudlav,
After a quick search it seems that yes the DeviceInfo should have BaudRate_XX, i.e., in camel case.
You can make a PR with the changes needed to support this, or wait and maybe during the weekend I can have a look.
Thanks
af-silva commentedon Mar 18, 2022
fix by #303 and #304