You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Define an explicit loaded signal representation #745
The loaded values may occupy p_signal, d_signal, e_p_signal, or e_d_signal. The physical and smooth_frames options determine which field and shape callers receive. sig_len counts base frames, while expanded channels can contain different numbers of samples.
Decisions to make
How should a read result state physical versus digital values and uniform versus expanded layout explicitly?
What shapes and dtypes should each representation guarantee, including missing values and multi-frequency signals?
Should conversions return a new representation or change the loaded object? What should rdsamp and any future read_signals return?
Activity
Make loaded single-segment signal modes explicit (#756)
Validate loaded modes for flattened multi-segment records (#757)