Description

@tompollard

Problem

The loaded values may occupy p_signal, d_signal, e_p_signal, or e_d_signal. The physical and smooth_frames options determine which field and shape callers receive. sig_len counts base frames, while expanded channels can contain different numbers of samples.

Decisions to make

  • How should a read result state physical versus digital values and uniform versus expanded layout explicitly?
  • What shapes and dtypes should each representation guarantee, including missing values and multi-frequency signals?
  • Should conversions return a new representation or change the loaded object? What should rdsamp and any future read_signals return?

Related: #376 (signal return API), #335 (smoothing behavior), #672 (signal and argument names).