Docs: a fifth of the mitral contact area with w_tol is self-interaction of a leaflet - #15
Merged
Merged
Conversation
…on of a leaflet Sorting the active contact pairs of the open mitral input at closure by their distance in the reference configuration: 268 of 3420 are between nearby points of the same leaflet (below 0.75), and the points they touch make up 17.5 of the contact area of 90.7; the pairs between opposing leaflets (above 3) account for 72.9, which is the contact area of the variant that excludes pairs by reference distance in place of the normal test. So that variant loses nothing that belongs to closure (decision K6), and the contact area reported with w_tol overstates coaptation by about a fifth on this valve. Recorded in the contact note, with a question for the FEBio team in the deviations note. Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com> Signed-off-by: Matthew Jolley <12954190+mattjolley@users.noreply.github.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
What does this change, and why?
A finding from the contact work, recorded in contact_in_run.md (section 6) with a question for the FEBio team in
deviations.md. Notes only; no code.Sorting the active contact pairs of the open mitral input at full closure by the distance between their two points in the reference configuration:
With the normal test
w_tol, about a fifth of the reported contact area (90.7 here, 89.6 in the stored FEBio run) comes from pairs between nearby points of the same leaflet, presumably at creases, and not from one leaflet meeting another. Excluding pairs by reference distance in place of the normal test, as the original formulation does for self-contact, removes exactly those pairs and leaves the rest: its contact area is 73.8. That closes the open reading under decision K6 for the smooth contact tier, and raises a question about the contact area as a measure of coaptation.Merged by the author; comments afterwards are welcome.
Validation