Repository navigation
Add a timeout override to get_charge_point_energy_meter_reading (#128) - #1
Merged
Merged
Conversation
The default httpx timeout is too short for this command's round trip to the physical charger. On an ONLINE, idle E2 with a CT clamp installed, a call raised ReadTimeout (treated as offline) under the default timeout, then succeeded in ~15-20s once given timeout=30. Adds an optional timeout parameter, defaulting to 30s, matching the existing pattern in get_charge_point_override. No behavior change for callers that already pass a timeout or for fast responses; only widens the window before treating the charger as offline. Related to #109. Co-authored-by: Dave <dave@integrationfox.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
The default httpx timeout is too short for this command's round trip to the physical charger. On an ONLINE, idle E2 with a CT clamp installed, a call raised ReadTimeout (treated as offline) under the default timeout, then succeeded in ~15-20s once given timeout=30.
Adds an optional timeout parameter, defaulting to 30s, matching the existing pattern in get_charge_point_override. No behavior change for callers that already pass a timeout or for fast responses; only widens the window before treating the charger as offline.
Related to hardbyte#109.